Taking a Temperature with the Exergen Temporal Scanner

The Exergen temporal scanner reads your temperature by scanning the temporal artery on your forehead—the blood vessel that runs across your temple. You hold the scanner about half an inch away from the skin, press and hold the button, and sweep it slowly across the forehead from the center toward the hairline. The reading appears on the screen in about one second. No contact with the skin is required, which makes it faster and more hygienic than oral or ear thermometers.

The scanner works best when your forehead is dry and free of hair, sweat, or makeup that might block the infrared sensor. If you have been wearing a hat or have just come in from cold weather, wait a few minutes before taking a reading—your forehead temperature may not yet match your core body temperature. The device is designed for ages 12 months and up.

Key Takeaways

  • Hold the scanner about half an inch from the center of the forehead and sweep slowly toward the hairline while pressing the button.
  • A reading takes about one second and appears on the screen without any need to touch the skin.
  • Wipe the sensor lens with a soft, dry cloth before use if it looks dusty or smudged.
  • Wait a few minutes after removing a hat or coming indoors before taking a reading, since forehead temperature lags behind core body temperature.
  • The scanner stores the last eight readings in memory, which you can scroll through using the memory button.

Step-by-Step Scanning Technique

Start by pressing the power button once. The screen will light up and show a ready symbol. Position the scanner so the sensor lens points at your forehead, about half an inch away—roughly the width of your pinky finger. The distance matters: too close and the reading may be inaccurate; too far and the sensor may not pick up the heat from the artery.

Place the scanner at the center of your forehead, between your eyebrows. Press and hold the scan button, then move the scanner slowly in one smooth motion toward your hairline, keeping the same distance from the skin. Do not lift the scanner or change direction mid-sweep. Release the button once you reach the hairline. The temperature will display on the screen within one second. If the reading seems too high or too low, wait 30 seconds and try again on the other side of the forehead.

For the most consistent results, take three readings and note the highest one. This accounts for minor variations in technique or skin temperature across the forehead. If readings differ by more than 0.5 degrees, your forehead may be too wet or too cold, or the sensor may need cleaning.

Cleaning and Caring for the Sensor

The infrared sensor lens is the most important part of the scanner. If dust, fingerprints, or dried sweat blocks the lens, readings will be inaccurate. Before each use, look at the lens—it should be clear and shiny. If you see smudges or dust, wipe it gently with a soft, dry, lint-free cloth. Do not use water, alcohol, or cleaning solutions, as these can damage the lens coating.

Store the scanner in a cool, dry place away from direct sunlight. Do not drop it or expose it to extreme heat or cold. If the scanner has been in a cold car or outside in winter, bring it indoors and let it sit for 15 minutes before using it. A cold sensor will read lower than the actual temperature.

Reading and Understanding the Display

The screen shows the temperature in either Fahrenheit or Celsius, depending on how the device is set. Most Exergen models come set to Fahrenheit. To switch units, hold down the mode button for three seconds until the display changes. The temperature reading appears as a number with one decimal place—for example, 98.6°F.

Below the temperature, the scanner may show a color indicator: green means normal, yellow means slightly elevated, and red means fever. These colors are guides only and should not replace your judgment. A fever is generally considered 100.4°F (38°C) or higher in adults and children over three months old. Newborns and infants under three months have different fever thresholds—consult your pediatrician about what temperature warrants concern for that age group.

Using the Memory Function

The Exergen temporal scanner stores the last eight temperature readings along with the time each was taken. This is useful if you are tracking a fever over several hours or days. To view stored readings, press the memory button on the side of the scanner. The screen will show the most recent reading first, with the time displayed below it. Press memory again to scroll backward through older readings.

The memory clears when you replace the batteries. If you need to keep a record of readings over a longer period, write them down in a notebook or take a photo of the screen. Some models allow you to read readings to a smartphone app, but this varies by model—check your user manual to see if your scanner has this feature.

Common Mistakes and How to Avoid Them

The most frequent error is holding the scanner too far from the forehead or at an angle. If the sensor does not point straight at the artery, it will read the surrounding skin temperature instead of the blood vessel temperature, giving you a reading that is too low. Practice the half-inch distance by holding your pinky finger next to the scanner—that is roughly the right gap.

Another common mistake is scanning too quickly. If you sweep the scanner across the forehead in less than one second, the sensor does not have time to register the heat. Slow down and count to yourself: "one Mississippi" should be about the right speed. Rushing also makes it straightforward to lift the scanner mid-sweep, which breaks the reading.

Taking a reading when your forehead is wet, sweaty, or covered with hair will give you a false low reading. Wipe your forehead dry with a tissue if you have just exercised, showered, or come in from the heat. If you have bangs or long hair covering your temples, brush it back before scanning. These steps take only a few seconds and make a real difference in accuracy.

Battery Replacement and Troubleshooting

The Exergen temporal scanner runs on two AAA batteries. When the battery icon appears on the screen, replace both batteries at the same time—do not mix old and new batteries. Open the battery compartment on the back of the scanner, remove the old batteries, and insert new ones with the positive end facing up. Close the compartment and press the power button to confirm the scanner works.

If the scanner does not turn on, check that the batteries are inserted correctly and that the compartment is fully closed. If it still does not work, try new batteries—old batteries may not have enough power to start the device. If the screen shows an error code or "Lo" (low battery), replace the batteries when ready. If the scanner turns on but gives wildly different readings each time, the sensor lens probably needs cleaning, or the device may need to be recalibrated—consult the user manual or contact Exergen customer service for recalibration instructions.

Frequently Asked Questions

Can I use the temporal scanner on a baby?

Yes, the Exergen temporal scanner is safe for infants 12 months and older. For babies under 12 months, use a rectal thermometer instead, as it is more accurate for that age group. Always consult your pediatrician about fever thresholds for infants, since they differ from older children and adults.

Why does my reading change each time I scan?

Small variations of 0.2 to 0.3 degrees are normal and reflect minor differences in where you position the scanner or how fast you sweep. If readings differ by more than 0.5 degrees, your forehead may be wet, cold, or partially covered by hair. Clean the sensor lens and try again on a dry forehead. If the problem continues, the sensor may need recalibration.

Is the temporal scanner more accurate than an oral thermometer?

Both are accurate when used correctly. The temporal scanner is faster and does not require the person to hold something in their mouth, which makes it easier for young children or people who are confused. Oral thermometers may be slightly more precise in some cases, but the difference is usually less than 0.5 degrees.

What should I do if the scanner reads much higher or lower than I expect?

First, check that your forehead is clean and dry, and that you are holding the scanner at the correct distance and angle. Wait 30 seconds and try again. If the reading is still unexpected, take your temperature with a different thermometer to compare. If the temporal scanner consistently reads very differently from other thermometers, the sensor may need cleaning or the device may need recalibration.

Can I use the temporal scanner on someone who is sleeping?

Yes, you can scan a sleeping person's forehead without waking them. The scanner does not touch the skin and makes no noise. Make sure the forehead is visible and not covered by hair or blankets, and use the same technique as you would for someone awake.